When other clubs ask purifan owners if they know of a better solution for replacing broken electrostatic smoke eaters, the answer is  usually to call purifan because it works and lasts a lifetime. Our highly skilled and experienced team can also integrate both air conditioning and heat reclaim systems by installing a daikin ventilation unit. Essentially, this allows you to have complete control over air conditioning and ventilation for your entire property. Our heat reclaim systems work by recovering heat energy that is lost through ventilation. While holding down the room temperature changes caused by the ventilation, the system interlocks with the air conditioning and re-releases the heat lost back into the room.

Fixed automatic water extinguishing systems shall be used in an enclosed garage comprising more than two underground storeys or located below the second underground storey. The requirement does not apply to a garage fire zone that has a direct entrance or exit from the building. A smoke and heat exhaust ventilation system activated by a smoke detection system shall be used in the fire area of an enclosed garage where this area has no direct entrance or exit from the building or where the area exceeds 1500 midx2. If the solution referred to in section 2 point 1 is used, the fire resistance class of the smoke and heat exhaust ventilation system ducts must comply with the requirements specified in art. 270 section 2 only regarding the fire tightness criterion (e). A) smoke ventilation systems, built using exhaust ducts (so-called duct systems), which remove heat and smoke through grilles located on the ventilation ducts.

Commercial smoke eaters installed in your bar, tavern, club, or restaurant can provide all your customers and staff with a pleasant social experience. The shut-off dampers should be installed in building partitions with the same fire resistance class. In special cases, they can be installed in partitions with a lower fire resistance class, but the smoke tightness criterion must still be maintained.. During normal operation, approximately 60% of the air is removed from the ceiling space, with the remaining 40% removed from floor level. During a fire outbreak, the bottom exhaust is cut off and 100% of the fire airflow  should be extracted through the top grilles.

The aim of the car park smoke control system is to provide a safe escape and that firefighting access is achievable, providing a smoke-free approach to within at least 10m of the seat of the fire. Car park venting systems are required to exhaust pollutants produced by vehicles and, in the event of a fire, clear smoke to assist the fire service. Depending on the type of car park, there are a variety of appropriate ventilation systems. Technical inspections of smoke extraction systems are carried out in accordance with [1], [3] And the manufacturer's technical and operating documentation. Most manufacturers require inspection of the electric and pneumatic smoke extraction system twice a year, every 6 months.

The device has been jumta  designed in accordance with standards for smoke detectors using light beams and short-circuit isolators in fire alarm systems (en 54-7 and en 54-17). The principle of the device operation is based on optical engineering. We are experienced in designing and implementing smoke removal and ventilation systems based on components by major polish and international manufacturers. In that regard, we are be able to advise the best solution which fulfils the investor’s requirements.